Industrial Series: GS8400-LEL

GS8400-LEL Fixed Combustible Gas Detector

Catalytic bead LEL detector for explosion prevention

Range
0-100 %LEL
Accuracy
±3% LEL
Rating
ATEX Zone 0, SIL 2
Sensor Life
>4 years
Product Overview

Overview

Fixed-point combustible gas detector using catalytic bead sensor for continuous %LEL monitoring. Poison-resistant catalyst with extended service life for petrochemical environments.

Key Highlights
  • ATEX Zone 0 certified (highest rating)
  • Poison-resistant catalyst formulation
  • Hot-swap sensor replacement
  • SIL 2 functional safety

Full Technical Specifications

Key Performance

Key Performance metrics for GS8400-LEL
Metric Value Status
Range 0-100%LEL confirmed
Accuracy ±3% LEL confirmed
Response <10 s T90 confirmed
Safety Rating ATEX Zone 0, SIL 2 confirmed
Sensor Life >4 years confirmed

Measurement

Measurement specifications for GS8400-LEL
SpecificationValue
Measuring PrincipleCatalytic Bead (pellistor)
Measurement Range0–100 %LEL
Accuracy±3% LEL
Response Time (T90)<10 s
Resolution1% LEL

Physical

Physical specifications for GS8400-LEL
SpecificationValue
Dimensions (W×H×D)170 × 175 × 110 mm
Weight2.1 kg
Housing Material316SS Ex d flameproof, IP66
MountingWall/pipe mount, 3/4″ NPT entries

Electrical

Electrical specifications for GS8400-LEL
SpecificationValue
Power Supply24 VDC (18–32 VDC), loop-powered
Analog Output4–20 mA with HART 7
Relay Outputs2 × SPDT alarm relays
Power Consumption<4 W

Environmental

Environmental specifications for GS8400-LEL
SpecificationValue
Operating Temperature-40 °C to +65 °C
Humidity0–99% RH
Ingress ProtectionIP66
VibrationIEC 60068-2-6

Certifications

Certifications specifications for GS8400-LEL
SpecificationValue
ATEXII 1G Ex d IIC T6 Gb (Zone 0)
Functional SafetySIL 2 per IEC 61508
PerformanceEN 60079-29-1
MarineDNV GL type-approved

Where This Analyzer Fits

This model is mapped to the following industry applications and process duties.

Petrochemical
Oil & Gas
Industrial Safety

Deployment Environments

Common process environments where this model is evaluated.

Petrochemical plants
Gas compressor stations
Tank farm monitoring
Loading/unloading areas

Certification Scope

Standards are listed with scope and status so engineering review can verify the applicable enclosure, area, and safety case.

Certification scope matrix for GS8400-LEL
Standard Scope Variant Status Document
ATEX II 1G Ex d IIC T6 Ga Zone 0 fixed combustible-gas detector installation Project variant approved On request
IEC 61508 SIL 2 Functional safety rating stated in key specs, specifications, and certification detail Project variant approved On request
EN 60079-29-1 Combustible gas detector performance standard listed in specifications and certification detail Project variant approved On request
IECEx / CSA / FM / UKCA / INMETRO Approvals listed in existing certification detail Project variant approved On request
IP66 Ingress rating listed in specifications and certification detail Project variant approved On request
CE ATEX SIL 2

Request Documentation

Request technical datasheets, user manuals, certificates, and application notes for this model.

Evidence Notes

case-study

Fixed %LEL detector architecture for coastal petrochemical duty

Application note based on the existing petrochemical scenario: catalytic-bead %LEL detection with poison-resistant catalyst formulation and hot-swap sensor replacement supports combustible-gas safety coverage in coastal plant areas. Fleet maintenance depends on inhibitor exposure, calibration-gas practice, and site proof-test policy.

Technical / Engineering Details

Technical & Engineering Details

Secondary engineering detail — expand each topic for the full measurement, envelope, sample-system, calibration, integration, maintenance and application evidence.

01 Measurement Principle and Limits

How the measurement is bounded

Catalytic bead pellistor detects combustible gas by catalytic oxidation for fixed-point %LEL safety monitoring.

Rejects

  • Process hydrocarbon concentration and hydrogen purity analysis duty

Requires

  • Methane in air at 50% LEL as the standard reference gas
  • Application-specific calibration gas and response factor for propane, butane, hydrogen, or other target gases
  • Sensor-replacement workflow through the hot-swap sensor design

Interferents and Limits

  • Silicones, lead, and sulfur compounds can deactivate catalytic bead elements
  • Hydrogen %LEL safety duty requires gas-specific response-factor review
02 Operating Envelope

Use these limits as selection inputs, then confirm sample condition, ambient exposure, and materials before quotation.

Ambient Temperature
-40-65 C
Humidity
0-99 %RH
relative humidity from Environmental specifications
Housing Material
316SS Ex d flameproof, IP66
Outside This Envelope
  • Process concentration measurement outside %LEL safety duty
  • Oxygen-depleted environments without detector-technology review
03 Sample System Boundary

Sampling mode, conditioning components, and exclusions define where the analyzer responsibility ends and the sample system begins.

Sampling Mode
fixed
Boundary Components
  • Fixed-point flameproof detector at the monitored location
  • Diffusion sensing at the catalytic bead; no extractive conditioning train
Boundary Exclusions
  • No external extractive conditioning system is declared for this fixed safety detector
04 Calibration & Validation

Calibration method, interval, and traceability are shown only when structured data is available.

Zero / Span Method

Methane in air at 50% LEL (2.5% v/v CH₄) as the standard reference; application-specific calibration gas with response factor for other target gases

Interval

Bump-test and proof-test interval to be set by the site functional-safety procedure

Span Gas Traceability

Application-specific calibration gas review for target gases such as methane, propane, butane, or hydrogen

05 I/O & Integration

Signal outputs and communication interfaces shown from the published specification fields on this product page.

Analog Output

4–20 mA with HART 7

Relay Outputs

2 × SPDT alarm relays

DAHS Review Note

Confirm protocol map, channel naming, alarm states, and reporting format during project integration review.

06 Maintenance & Spares site-specific

Tasks, consumables, and access items are shown only when structured maintenance data is available.

Service Tasks
  • Bump-test and proof-test interval to be set by the site functional-safety procedure
  • Hot-swap sensor replacement through the quick-disconnect bayonet workflow
  • Poisoning-risk review where silicones, lead, or sulfur compounds may reach the catalytic bead
  • Application-specific calibration gas review for target gases such as methane, propane, butane, or hydrogen
Consumables
  • Catalytic bead sensor head
  • Methane in air at 50% LEL or application-specific calibration gas
07 Application Evidence

Application context from complex industrial environments.

Case Study Petrochemical

Application Context

Petrochemical complexes commissioning new propylene plants in coastal environments need 100+ LEL detectors that survive salt-air corrosion and silicone vapors — duty profiles that historically poison standard catalytic-bead sensors within months.

Architecture Response

GS8400-LEL with a poison-resistant catalyst formulation maintains accuracy across multi-year service in coastal duty, and hot-swap sensor replacement keeps maintenance windows short across the full detector fleet.

Coastal-Duty Reliability Poison-resistant catalyst · hot-swap sensor replacement
Selection Questions

Frequently Asked Questions

What does ATEX Zone 0 certification mean?

Zone 0 is the most hazardous classification where explosive gas is present continuously or for long periods. The GS8400-LEL uses a flameproof (Ex d) enclosure tested for worst-case internal explosion containment.

What is sensor poisoning and how is it prevented?

Certain compounds (silicones, lead, sulfur) can permanently deactivate catalytic bead elements. The poison-resistant catalyst uses a proprietary rare-earth formulation that resists common inhibitors.

How does hot-swap sensor replacement work?

The sensor head is mounted in a quick-disconnect bayonet fitting. Twist and pull to remove, insert replacement — no tools, no enclosure disassembly, no gas-free certificate needed.

What calibration gas should I use?

Methane in air at 50% LEL (2.5% v/v CH₄) is the standard reference. For specific target gases (propane, butane, hydrogen), use application-specific calibration gas with the appropriate response factor.

Does it detect hydrogen?

Yes, catalytic beads respond to all combustible gases including hydrogen. For hydrogen-specific applications requiring faster response, consider the GS8410-LEL with IR detection.

Review GS8400-LEL against site conditions

Send gas range, sample temperature, pressure, moisture, and certification needs before final model selection.