Industrial Series: GS-WCL500

Multi-Parameter Water Quality Panel

Integrated chlorine + pH + turbidity + temperature panel with selectable amperometric or DPD method

Chlorine Range
0–20 ppm (free or total)
Accuracy
±0.02 ppm
Output
4× 4-20mA, RS485, Modbus TCP/IP
Alarm Relays
4× SPDT (configurable)
Product Overview

Overview

The GS-WCL500 is an integrated multi-parameter water quality panel that combines chlorine (amperometric or DPD, selectable), pH, turbidity, and temperature on a single 7″ touchscreen controller — reducing cabinet footprint, wiring, and commissioning effort for drinking-water, wastewater, and food-grade process installations.

Key Highlights
  • Selectable amperometric or DPD chlorine method
  • Integrated pH, turbidity, and temperature sensors
  • 7″ color touchscreen with data logging
  • Modbus TCP/IP over Ethernet for SCADA integration
  • 4 configurable SPDT alarm relays (high/low)
  • IP65 / NEMA 4X wall-mount enclosure

Full Technical Specifications

Key Performance

Key Performance metrics for GS-WCL500
Metric Value Status
Chlorine Range 0-20 ppm free or total confirmed
Accuracy ±0.02 ppm confirmed
Output 4x 4-20mA, RS485, Modbus TCP/IP confirmed
Alarm Relays 4x SPDT configurable confirmed

Specifications

Specifications for GS-WCL500
SpecificationValue
Chlorine Range0–20 ppm (free or total)
Accuracy±0.02 ppm
Output4× 4-20mA, RS485, Modbus TCP/IP
Alarm Relays4× SPDT (configurable)

Deployment Environments

Common process environments where this model is evaluated.

Municipal drinking water treatment plants
Wastewater multi-parameter compliance monitoring
Food & beverage CIP water quality control
Cooling tower integrated biocide and pH management

Certification Scope

Standards are listed with scope and status so engineering review can verify the applicable enclosure, area, and safety case.

Certification scope matrix for GS-WCL500
Standard Scope Variant Status Document
CE Approval listed in v1 certification badges Project variant approved On request
IP65 / NEMA 4X Wall-mount enclosure ratings listed in v1 certification badges and feature list Project variant approved On request
CE IP65 NEMA 4X

Request Documentation

Request technical datasheets, user manuals, certificates, and application notes for this model.

Evidence Notes

application-note

Integrated water-quality panel architecture

The v1 applications place this panel in municipal drinking water, wastewater, food and beverage CIP, and cooling-tower control. The architecture combines selectable chlorine measurement with pH, turbidity, temperature, SCADA outputs, and alarm relays for aqueous water-quality control.

Technical / Engineering Details

Technical & Engineering Details

Secondary engineering detail — expand each topic for the full measurement, envelope, sample-system, calibration, and maintenance information.

01 Measurement Principle

How the measurement is bounded

Multi-parameter water-quality panel combines selectable amperometric or DPD chlorine measurement with pH, turbidity, and temperature channels.

Requires

  • Method selection between amperometric and DPD chlorine measurement
  • pH, turbidity, and temperature sensors configured for the water application
  • SCADA mapping for the four analog outputs, RS485, Modbus TCP/IP, and alarm relays

Interferents and Limits

  • Turbidity and color can affect DPD photometric workflows
  • pH shifts can change free-chlorine speciation
  • Fouling on amperometric sensors changes response if maintenance is not matched to water quality
  • Single-parameter chlorine duty may not need a multi-parameter panel
  • Water temperature, pressure, flow, and pH numeric ranges are not stated in v1 source data
  • Chlorine-air area monitoring is outside this aqueous panel boundary
02 Operating Envelope

Use these limits as selection inputs, then confirm sample condition, ambient exposure, and materials before quotation.

Temperature
water temperature channel is included, but numeric range is not stated in v1 source data
Pressure
sample-line pressure range not stated in v1 source data
Outside This Envelope
  • Use without method selection between amperometric and DPD chlorine measurement
  • Use without SCADA and alarm mapping review for multi-channel outputs
  • Use as a chlorine-air area monitor
03 Sample System Boundary

Sampling mode, conditioning components, and exclusions define where the analyzer responsibility ends and the sample system begins.

Sampling Mode
extractive
Boundary Components
  • wall-mount controller panel
  • selectable chlorine channel
  • pH sensor
  • turbidity sensor
  • temperature sensor
  • sample bypass or online flow path
Boundary Exclusions
  • Not a stack, duct, or ambient-air chlorine detector
04 Calibration & Validation site-specific

Calibration method, interval, and traceability are shown only when structured data is available.

Zero / Span Method

Calibration workflow depends on selected amperometric or DPD chlorine method plus pH, turbidity, and temperature channels

Interval

Not stated in v1 source data

05 Maintenance & Spares site-specific

Tasks, consumables, and access items are shown only when structured maintenance data is available.

Service Tasks
  • Maintain the selected chlorine method path, either amperometric or DPD
  • Verify pH, turbidity, and temperature channels during scheduled water-quality checks
  • Confirm alarm relay and SCADA mapping after commissioning or method changes
  • Review sensor fouling risk for wastewater, food-grade CIP, and cooling-water duty
Consumables
  • Selected chlorine-method consumables
  • pH sensor service parts
  • turbidity cell service parts
  • calibration standards

Review GS-WCL500 against site conditions

Send gas range, sample temperature, pressure, moisture, and certification needs before final model selection.