Multi-Parameter Water Quality Panel
Integrated chlorine + pH + turbidity + temperature panel with selectable amperometric or DPD method
- Chlorine Range
- 0–20 ppm (free or total)
- Accuracy
- ±0.02 ppm
- Output
- 4× 4-20mA, RS485, Modbus TCP/IP
- Alarm Relays
- 4× SPDT (configurable)
Overview
The GS-WCL500 is an integrated multi-parameter water quality panel that combines chlorine (amperometric or DPD, selectable), pH, turbidity, and temperature on a single 7″ touchscreen controller — reducing cabinet footprint, wiring, and commissioning effort for drinking-water, wastewater, and food-grade process installations.
- Selectable amperometric or DPD chlorine method
- Integrated pH, turbidity, and temperature sensors
- 7″ color touchscreen with data logging
- Modbus TCP/IP over Ethernet for SCADA integration
- 4 configurable SPDT alarm relays (high/low)
- IP65 / NEMA 4X wall-mount enclosure
Full Technical Specifications
Key Performance
| Metric | Value | Status |
|---|---|---|
| Chlorine Range | 0-20 ppm free or total | confirmed |
| Accuracy | ±0.02 ppm | confirmed |
| Output | 4x 4-20mA, RS485, Modbus TCP/IP | confirmed |
| Alarm Relays | 4x SPDT configurable | confirmed |
Specifications
| Specification | Value |
|---|---|
| Chlorine Range | 0–20 ppm (free or total) |
| Accuracy | ±0.02 ppm |
| Output | 4× 4-20mA, RS485, Modbus TCP/IP |
| Alarm Relays | 4× SPDT (configurable) |
Deployment Environments
Common process environments where this model is evaluated.
Certification Scope
Standards are listed with scope and status so engineering review can verify the applicable enclosure, area, and safety case.
| Standard | Scope | Variant | Status | Document |
|---|---|---|---|---|
| CE | Approval listed in v1 certification badges | Project variant | approved | On request |
| IP65 / NEMA 4X | Wall-mount enclosure ratings listed in v1 certification badges and feature list | Project variant | approved | On request |
Request Documentation
Request technical datasheets, user manuals, certificates, and application notes for this model.
Evidence Notes
Integrated water-quality panel architecture
The v1 applications place this panel in municipal drinking water, wastewater, food and beverage CIP, and cooling-tower control. The architecture combines selectable chlorine measurement with pH, turbidity, temperature, SCADA outputs, and alarm relays for aqueous water-quality control.
Technical & Engineering Details
Secondary engineering detail — expand each topic for the full measurement, envelope, sample-system, calibration, and maintenance information.
01 Measurement Principle
How the measurement is bounded
Multi-parameter water-quality panel combines selectable amperometric or DPD chlorine measurement with pH, turbidity, and temperature channels.
Requires
- Method selection between amperometric and DPD chlorine measurement
- pH, turbidity, and temperature sensors configured for the water application
- SCADA mapping for the four analog outputs, RS485, Modbus TCP/IP, and alarm relays
Interferents and Limits
- Turbidity and color can affect DPD photometric workflows
- pH shifts can change free-chlorine speciation
- Fouling on amperometric sensors changes response if maintenance is not matched to water quality
- Single-parameter chlorine duty may not need a multi-parameter panel
- Water temperature, pressure, flow, and pH numeric ranges are not stated in v1 source data
- Chlorine-air area monitoring is outside this aqueous panel boundary
02 Operating Envelope
Use these limits as selection inputs, then confirm sample condition, ambient exposure, and materials before quotation.
- Use without method selection between amperometric and DPD chlorine measurement
- Use without SCADA and alarm mapping review for multi-channel outputs
- Use as a chlorine-air area monitor
03 Sample System Boundary
Sampling mode, conditioning components, and exclusions define where the analyzer responsibility ends and the sample system begins.
- wall-mount controller panel
- selectable chlorine channel
- pH sensor
- turbidity sensor
- temperature sensor
- sample bypass or online flow path
- Not a stack, duct, or ambient-air chlorine detector
04 Calibration & Validation site-specific
Calibration method, interval, and traceability are shown only when structured data is available.
Zero / Span Method
Calibration workflow depends on selected amperometric or DPD chlorine method plus pH, turbidity, and temperature channels
Interval
Not stated in v1 source data
05 Maintenance & Spares site-specific
Tasks, consumables, and access items are shown only when structured maintenance data is available.
- Maintain the selected chlorine method path, either amperometric or DPD
- Verify pH, turbidity, and temperature channels during scheduled water-quality checks
- Confirm alarm relay and SCADA mapping after commissioning or method changes
- Review sensor fouling risk for wastewater, food-grade CIP, and cooling-water duty
- Selected chlorine-method consumables
- pH sensor service parts
- turbidity cell service parts
- calibration standards
Review GS-WCL500 against site conditions
Send gas range, sample temperature, pressure, moisture, and certification needs before final model selection.