Fixed Chlorine Detector
Fixed-point Cl₂ safety detector with UV-DOAS for area monitoring and leak detection
- Range
- 0–50 ppm Cl₂
- Accuracy
- ±5% of reading or ±0.05 ppm
- Response
- <10s T90
- Output
- 4-20mA, RS-485 Modbus, 3 relays
Overview
The GS8601-CL2 is a fixed-point chlorine gas detector using UV-DOAS technology for area monitoring in chlor-alkali plants, chemical storage facilities, and water treatment sites with ATEX Zone 1 certification.
- UV-DOAS sensor with stated 5+ year lifetime
- ATEX Zone 1 flameproof enclosure (IP66)
- Three configurable alarm relays (TWA/STEL/IDLH)
- Integrated audible/visual alarm beacon
- Daisy-chain up to 16 units on RS-485 bus
- Self-diagnostic with automatic fault reporting
- Cl₂ in CEMS: the wall-mounted ZS9100 UV-DOAS CEMS covers stack Cl₂ alongside SO₂/NO/NO₂/NH₃/O₂ in one enclosure
Full Technical Specifications
Key Performance
| Metric | Value | Status |
|---|---|---|
| Range | 0-50 ppm Cl2 | confirmed |
| Accuracy | ±5% of reading or ±0.05 ppm | confirmed |
| Response | <10s T90 | confirmed |
| Output | 4-20mA, RS-485 Modbus, 3 relays | confirmed |
Specifications
| Specification | Value |
|---|---|
| Range | 0–50 ppm Cl₂ |
| Accuracy | ±5% of reading or ±0.05 ppm |
| Response | <10s T90 |
| Output | 4-20mA, RS-485 Modbus, 3 relays |
Deployment Environments
Common process environments where this model is evaluated.
Certification Scope
Standards are listed with scope and status so engineering review can verify the applicable enclosure, area, and safety case.
| Standard | Scope | Variant | Status | Document |
|---|---|---|---|---|
| ATEX Zone 1 | Zone 1 flameproof enclosure stated in v1 description and features | Project variant | approved | On request |
| SIL 2 | Functional-safety badge listed in v1 certification badges; proof-test details not stated in v1 source data | Project variant | approved | On request |
| IP66 | Ingress rating stated in v1 feature list | Project variant | approved | On request |
| CE | Approval listed in v1 certification badges | Project variant | approved | On request |
Request Documentation
Request technical datasheets, user manuals, certificates, and application notes for this model.
Evidence Notes
Fixed gas-phase chlorine safety architecture
The v1 application set covers perimeter monitoring, water-treatment facility safety, chemical storage and loading, and emergency leak detection. This path is gas-phase fixed detection with UV-DOAS sensing, relay alarms, local alarm beacon, RS-485 networking, and self-diagnostics.
Technical & Engineering Details
Secondary engineering detail — expand each topic for the full measurement, envelope, and maintenance information.
01 Measurement Principle and Limits
How the measurement is bounded
Fixed-point UV-DOAS chlorine gas detection applies optical absorption to area monitoring and leak-detection duty.
Requires
- Alarm relay setpoints matched to the site TWA, STEL, or IDLH policy
- Optical-path and self-diagnostic checks included in the site proof-test routine
- Gas-phase placement review for chlor-alkali, storage, loading, and water-treatment safety areas
Interferents and Limits
- SO2, HCl, and HF spectral overlap can require matrix review in mixed acid-gas areas
- ClO2 or other UV-absorbing chlorine compounds should be reviewed separately from Cl2
- Aerosols, fog, or condensation near the detector can affect UV optical response
- Aqueous residual chlorine panels are outside this gas-detector boundary
- Process control above the declared 0-50 ppm safety range
- Hazardous-area scope beyond ATEX Zone 1 is not declared in v1 source data
02 Operating Envelope
Use these limits as selection inputs, then confirm sample condition, ambient exposure, and materials before quotation.
- Cl2 gas
- mixed acid-gas spectral-overlap review
- Aqueous free or total chlorine residual monitoring
- Process analyzer duty above the fixed-detector range
- Installation outside ATEX Zone 1 or IP66 assumptions without certification review
03 Maintenance & Spares site-specific
Tasks, consumables, and access items are shown only when structured maintenance data is available.
- Verify TWA, STEL, and IDLH alarm relay configuration against the site safety basis
- Check audible/visual alarm beacon and RS-485 daisy-chain communication during proof-test rounds
- Review UV optical response where Cl2 coexists with SO2, HCl, HF, ClO2, aerosols, fog, or condensation
Fixed-point flameproof enclosure with self-diagnostic and automatic fault reporting listed in v1 features
Frequently Asked Questions
What does the GS8601-CL2 measure, and how?
The GS8601-CL2 is a fixed-point UV-DOAS chlorine gas detector that applies optical absorption to area monitoring and leak-detection duty. The published range is 0–50 ppm Cl₂ with ±5% of reading or ±0.05 ppm accuracy and a <10s T90 response; outputs are 4-20mA, RS-485 Modbus, and 3 relays.
How are the GS8601-CL2 alarms configured and networked?
It provides three configurable alarm relays with setpoints matched to the site TWA, STEL, or IDLH policy, plus an integrated audible/visual alarm beacon. Up to 16 units can be daisy-chained on the RS-485 bus, and the detector self-diagnoses with automatic fault reporting.
Where should the GS8601-CL2 be placed, and what can affect the reading?
Placement should follow a gas-phase review for chlor-alkali, storage, loading, and water-treatment safety areas. SO2, HCl, and HF spectral overlap can require a matrix review in mixed acid-gas areas; ClO2 or other UV-absorbing chlorine compounds should be reviewed separately from Cl2; and aerosols, fog, or condensation near the detector can affect the UV optical response.
Can the GS8601-CL2 be used as a process analyzer or for chlorine in water?
No on both counts. It is a fixed-point safety detector: process-analyzer duty above the declared 0–50 ppm safety range is outside its envelope, and aqueous residual chlorine measurement is outside the gas-detector boundary — that water-domain work belongs to the GS-WCL panel family.
What hazardous-area rating does the GS8601-CL2 carry?
It uses an ATEX Zone 1 flameproof enclosure with an IP66 ingress rating. Hazardous-area scope beyond ATEX Zone 1 is not declared in the v1 source data, so installation outside the ATEX Zone 1 or IP66 assumptions requires a separate certification review.
What approvals does the GS8601-CL2 carry?
CE, ATEX, and SIL 2 approvals are listed, with an ATEX Zone 1 flameproof enclosure and an IP66 ingress rating. The SIL 2 proof-test details are not stated in the v1 source data, so the functional-safety case should be confirmed during engineering review.
Review GS8601-CL2 against site conditions
Send gas range, sample temperature, pressure, moisture, and certification needs before final model selection.