Industrial Series: GS8320-H2S

GS8320-H2S Portable H₂S Detector

Personal H₂S safety monitor with vibration and audible alarm

Range
0-200 ppm H₂S
Alarm
95 dB audible + vibration
Weight
110 g
Runtime
2 years (always-on)
Product Overview

Overview

Clip-on personal H₂S monitor for worker safety. Loud audible alarm, vibration alert, and bright LED warning for immediate hazard notification in noisy environments.

Key Highlights
  • Clip-on design, 110g weight
  • 2-year continuous runtime
  • Man-down motion alarm
  • Event logging with IR download

Full Technical Specifications

Key Performance

Key Performance metrics for GS8320-H2S
Metric Value Status
Range 0-200ppm H₂S confirmed
Alarm 95 dB audible + vibration confirmed
Response <15 s T90 confirmed
Runtime 2 years continuous always-on confirmed
Weight 110g confirmed

Measurement

Measurement specifications for GS8320-H2S
SpecificationValue
Measuring PrincipleElectrochemical
Measurement Range0–200 ppm H₂S
Accuracy±5% of reading or ±2 ppm
Response Time (T90)<15 s
Resolution0.1 ppm

Physical

Physical specifications for GS8320-H2S
SpecificationValue
Dimensions (W×H×D)90 × 58 × 32 mm
Weight110 g
Housing MaterialPolycarbonate IP67
ClipStainless steel alligator clip

Electrical

Electrical specifications for GS8320-H2S
SpecificationValue
Battery3.6 V lithium (non-rechargeable)
Runtime2 years continuous always-on
Data LoggingEvent log 100 events
DownloadIR port

Environmental

Environmental specifications for GS8320-H2S
SpecificationValue
Operating Temperature-20 °C to +55 °C
Storage Temperature-30 °C to +60 °C
Humidity15–90 % RH
VibrationMIL-STD-810G

Certifications

Certifications specifications for GS8320-H2S
SpecificationValue
Hazardous AreaATEX II 1G Ex ia IIC T4
Ingress ProtectionIP67
PerformanceEN 60079-29-1
Drop Test3 m onto concrete

Where This Analyzer Fits

This model is mapped to the following industry applications and process duties.

Oil & Gas
Industrial Safety
Emergency Response

Deployment Environments

Common process environments where this model is evaluated.

Personal safety monitoring
Confined space entry
Well testing operations
Emergency response

Certification Scope

Standards are listed with scope and status so engineering review can verify the applicable enclosure, area, and safety case.

Certification scope matrix for GS8320-H2S
Standard Scope Variant Status Document
ATEX II 1G Ex ia IIC T4 Ga Zone 0 personal H₂S detector installation Project variant approved On request
IECEx / CSA / FM / MSHA Approvals listed in existing certification detail Project variant approved On request
EN 60079-29-1 Gas detector performance standard listed in specifications and certification detail Project variant approved On request
IEC 60079-0/11 / ANSI/ISA 92.00.01 Standards listed in existing certification detail Project variant approved On request
IP67 Ingress rating listed in specifications and certification detail Project variant approved On request
CE

Request Documentation

Request technical datasheets, user manuals, certificates, and application notes for this model.

Evidence Notes

case-study

Personal H₂S monitor coverage architecture for well-site rotations

Application note based on the existing oil-and-gas exploration scenario: always-on personal H₂S monitors with man-down alarm and event-log download support worker-coverage planning for well-site rotations. Fleet planning depends on bump-test practice, event-log handling, and replacement policy.

Technical / Engineering Details

Technical & Engineering Details

Secondary engineering detail — expand each topic for the full measurement, envelope, sample-system, calibration, integration, maintenance and application evidence.

01 Measurement Principle and Limits

How the measurement is bounded

Electrochemical H₂S cell supports personal safety monitoring with audible, vibration, LED, and man-down alarm functions.

Requires

  • Daily bump test with 25 ppm H₂S gas using the BT-100 bump test station
  • IR download workflow when event logs are needed
  • Use within the stated temperature and humidity limits

Interferents and Limits

  • Electrochemical H₂S cells require site review for reactive-gas cross-sensitivity such as CL₂ or SO₂
  • Sensor poisoning or contamination risk should be reviewed after abnormal exposure events
  • Personal safety monitor duty, not process H₂S quality control
  • Operation outside the stated temperature and humidity ranges
02 Operating Envelope

Use these limits as selection inputs, then confirm sample condition, ambient exposure, and materials before quotation.

Ambient Temperature
-20-55 C
Humidity
15-90 %RH
relative humidity from Environmental specifications
Housing Material
Polycarbonate IP67
Outside This Envelope
  • Process-control measurement duty
  • Use outside the stated personal-detector environmental range
03 Sample System Boundary

Sampling mode, conditioning components, and exclusions define where the analyzer responsibility ends and the sample system begins.

Sampling Mode
portable
Boundary Components
  • clip-on personal detector
  • audible alarm
  • vibration alert
  • LED warning
  • IR event-log download
Boundary Exclusions
  • Not configured as an extractive process analyzer
04 Calibration & Validation site-specific

Calibration method, interval, traceability, and audit support are shown only when structured data is available.

Zero / Span Method

Daily bump test with 25 ppm H₂S gas using BT-100 bump test station; calibration interval not stated in v1 source data

Interval

Daily bump test; calibration interval not stated in v1 source data

Span Gas Traceability

25 ppm H₂S bump-test gas stated in FAQ

05 I/O & Integration

Signal outputs and communication interfaces shown from the published specification fields on this product page.

Download

IR port

Data Logging

Event log 100 events

Alarm

95 dB audible + vibration

Integration Review Note

Confirm event-log download workflow, alarm configuration, and fleet documentation format during project integration review.

06 Maintenance & Spares site-specific

Tasks, consumables, and access items are shown only when structured maintenance data is available.

Service Tasks
  • Daily bump test with 25 ppm H₂S gas using BT-100 bump test station
  • Event-log download through the IR port when fleet documentation is needed
  • Battery and detector replacement planning against the stated continuous-runtime reference
Consumables
  • 25 ppm H₂S bump-test gas
  • BT-100 bump test station consumables if used by site procedure

Cell Life

2-year continuous always-on runtime stated in specifications.

07 Application Evidence

Application context from complex industrial environments.

Case Study Oil & Gas Exploration

Application Context

Drilling contractors equipping 200+ well-site workers with personal H₂S monitors face high failure rates from clip-on units with non-replaceable batteries, which forces frequent fleet replacement and leaves blind spots in worker coverage.

Architecture Response

GS8320-H2S with a 2-year always-on battery removes the consumable-battery failure path, and the man-down alarm feature supports earlier worker-exposure detection during well-site rotations.

Worker-Coverage Architecture 2-year battery · man-down alarm
Selection Questions

Frequently Asked Questions

Why does the battery last 2 years?

The ultra-low-power electrochemical sensor and ASIC design draw <50 µA in normal monitoring mode. The 3.6 V lithium cell provides continuous always-on operation without charging.

What is the man-down alarm?

If the detector detects no motion for a configurable period (default 30 seconds), it triggers a loud alarm to alert nearby workers that the wearer may be incapacitated.

Can I use it in ATEX Zone 0?

Yes, it is certified ATEX II 1G Ex ia IIC T4 Ga for Zone 0 — the most explosive atmospheres, including hydrogen and acetylene environments.

How do I download event logs?

Use the infrared (IR) port with the GasLink docking station. Event logs include alarm triggers, peak readings, TWA, STEL, and man-down events with timestamps.

Is it bump test compatible?

Yes, daily bump test with 25 ppm H₂S gas using the BT-100 bump test station. The station auto-records pass/fail for fleet compliance documentation.

Review GS8320-H2S against site conditions

Send gas range, sample temperature, pressure, moisture, and certification needs before final model selection.