Industrial Series: GS8310-H2S

GS8310-H2S Fixed H₂S Safety Detector

SIL 2 rated fixed-point H₂S gas detector for personnel safety

Range
0-100 ppm H₂S
Alarm
10 / 15 ppm (adjustable)
Rating
SIL 2, ATEX Zone 1
Sensor Life
>3 years
Product Overview

Overview

Fixed-point hydrogen sulfide detector with electrochemical sensor for continuous workplace safety monitoring. Dual alarm relays, 4-20mA output, and optional wireless mesh networking.

Key Highlights
  • SIL 2 functional safety rated
  • Dual alarm relays + 4-20mA
  • Optional wireless WirelessHART
  • Field-replaceable sensor in <60s

Full Technical Specifications

Key Performance

Key Performance metrics for GS8310-H2S
Metric Value Status
Range 0-100ppm H₂S confirmed
Alarm 10 / 15 ppm adjustable confirmed
Response <15 s T90 confirmed
Safety Rating SIL 2, ATEX Zone 1 confirmed
Sensor Life >3 years confirmed

Measurement

Measurement specifications for GS8310-H2S
SpecificationValue
Measuring PrincipleElectrochemical (3-electrode)
Measurement Range0–100 ppm H₂S
Accuracy±2 ppm or ±5% of reading
Response Time (T90)<15 s
Resolution0.1 ppm

Physical

Physical specifications for GS8310-H2S
SpecificationValue
Dimensions (W×H×D)170 × 175 × 110 mm
Weight1.8 kg
Housing Material316SS / Aluminum Ex d flameproof
MountingWall/pipe mount (2″ NPT/M20 entries)

Electrical

Electrical specifications for GS8310-H2S
SpecificationValue
Power Supply24 VDC (18–32 VDC)
Analog Output4–20 mA loop-powered
Digital OutputHART 7 / optional WirelessHART
Relay Outputs2 × SPDT alarm
Power Consumption<3.5 W

Environmental

Environmental specifications for GS8310-H2S
SpecificationValue
Operating Temperature-40 °C to +65 °C
Humidity0–99 % RH (with weather protection)
Ingress ProtectionIP66/67
VibrationIEC 60068-2-6

Certifications

Certifications specifications for GS8310-H2S
SpecificationValue
Hazardous AreaATEX II 2G Ex d IIC T6
Functional SafetySIL 2 per IEC 61508
PerformanceEN 60079-29-1
MarineDNV GL (optional)

Where This Analyzer Fits

This model is mapped to the following industry applications and process duties.

Oil & Gas
Petrochemical
Industrial Safety

Deployment Environments

Common process environments where this model is evaluated.

Oil & gas platforms
Refinery process areas
Wastewater treatment
Confined space perimeter

Certification Scope

Standards are listed with scope and status so engineering review can verify the applicable enclosure, area, and safety case.

Certification scope matrix for GS8310-H2S
Standard Scope Variant Status Document
ATEX II 2G Ex d IIC T6 Gb Zone 1 fixed H₂S detector installation Project variant approved On request
IEC 61508 SIL 2 Functional safety rating stated in key specs, specifications, and certification detail Project variant approved On request
EN 60079-29-1 Gas detector performance standard listed in specifications and certification detail Project variant approved On request
IECEx / CSA / FM / UKCA / INMETRO Approvals listed in existing certification detail Project variant approved On request
IP66/67 Ingress rating listed in specifications and certification detail Project variant approved On request
CE ATEX SIL 2

Request Documentation

Request technical datasheets, user manuals, certificates, and application notes for this model.

Evidence Notes

case-study

Fixed H₂S detector maintenance workflow for SIL 2 safety coverage

Application note based on the existing offshore safety scenario: field-replaceable electrochemical sensors and SIL 2 certification support detector-maintenance planning for H₂S safety networks. Turnaround planning depends on site access, proof-test policy, and hazardous-area work controls.

Technical / Engineering Details

Technical & Engineering Details

Secondary engineering detail — expand each topic for the full measurement, envelope, sample-system, calibration, integration, maintenance and application evidence.

01 Measurement Principle and Limits

How the measurement is bounded

Three-electrode electrochemical H₂S cell supports fixed-point workplace safety detection.

Rejects

  • Targeted electrochemical H₂S cell for fixed-point safety duty
  • Out-of-scope process H₂S quality-control measurement

Requires

  • Alarm setpoints configured through HART or local magnetic switches
  • Sensor cartridge replacement through the field-service workflow stated in v1 FAQ
  • Weather protection when humidity approaches the stated operating boundary

Interferents and Limits

  • Electrochemical H₂S cells require site review for reactive-gas cross-sensitivity such as CL₂ or SO₂
  • Sensor poisoning or contamination risk should be reviewed after abnormal exposure events
  • Safety detector duty, not process H₂S quality control
  • Humidity service outside the stated weather-protected boundary
  • Extreme cold below the base rating requires optional heated sensor module review
02 Operating Envelope

Use these limits as selection inputs, then confirm sample condition, ambient exposure, and materials before quotation.

Ambient Temperature
-40-65 C
Humidity
0-99 %RH
relative humidity with weather protection
Housing Material
316SS / Aluminum Ex d flameproof
Outside This Envelope
  • Process-control measurement duty
  • Operation below the base cold rating without heated sensor module review
03 Sample System Boundary

Sampling mode, conditioning components, and exclusions define where the analyzer responsibility ends and the sample system begins.

Sampling Mode
fixed
Boundary Components
  • Fixed-point flameproof detector at the monitored location
  • Diffusion sensing at the cell face; no extractive conditioning train
Boundary Exclusions
  • No external extractive conditioning system is declared for this fixed safety detector
04 Calibration & Validation not published

Calibration method, interval, traceability, and audit support are shown only when structured data is available.

Zero / Span Method

Alarm setpoints configured through HART or local magnetic switches

Interval

Calibration interval not stated in v1 source data

05 I/O & Integration

Signal outputs and communication interfaces shown from the published specification fields on this product page.

Analog Output

4–20 mA loop-powered

Digital Output

HART 7 / optional WirelessHART

Relay Outputs

2 × SPDT alarm

DAHS Review Note

Confirm protocol map, channel naming, alarm states, and reporting format during project integration review.

06 Maintenance & Spares site-specific

Tasks, consumables, and access items are shown only when structured maintenance data is available.

Service Tasks
  • Field sensor-cartridge replacement using the hot-swap workflow stated in v1 FAQ
  • Proof-test and bump-test interval to be set by the site functional-safety procedure
  • Alarm-setpoint review through HART or local magnetic switches
  • Optional heated sensor module review for cold-climate installations
Consumables
  • H₂S sensor cartridge
Service access: field-replaceable sensor cartridge stated in feature list and FAQ · Cell life >3 years
07 Application Evidence

Application context from complex industrial environments.

Case Study Offshore Oil & Gas

Application Context

Offshore platform operators upgrading to SIL 2 H₂S detection on 40+ field detectors face long sensor-changeout times — at 45 minutes per detector, the platform-wide turnaround drives extended hot-work and spread-rate exposure.

Architecture Response

GS8310-H2S with field-replaceable sensors compresses changeout to under 60 seconds per detector, so platform-wide SIL 2 turnarounds avoid the multi-shift scaffolding and hot-work exposure of legacy designs.

Maintenance Workflow Field-replaceable sensor · sub-60-second changeout
Selection Questions

Frequently Asked Questions

What does SIL 2 mean for gas detection?

SIL 2 (Safety Integrity Level 2) per IEC 61508 means the detector meets a probability of failure on demand between 10⁻³ and 10⁻². This is required for safety-critical gas detection in most oil & gas facilities.

How fast can I replace the sensor in the field?

Under 60 seconds. The sensor cartridge is hot-swappable without removing the detector from the wall or breaking the flameproof enclosure seal.

What is WirelessHART and when should I use it?

WirelessHART (IEC 62591) provides wireless mesh networking for locations where running cable is impractical — retrofit installations, temporary monitoring, or remote well pads.

What alarm setpoints are recommended for H₂S?

Typical: Low alarm at 5–10 ppm (OSHA ceiling limit), High alarm at 15–20 ppm (evacuation trigger). Setpoints are configurable via HART or local magnetic switches.

Does it work in extreme cold environments?

Yes, rated to -40 °C. Optional heated sensor module available for Arctic installations down to -55 °C.

Review GS8310-H2S against site conditions

Send gas range, sample temperature, pressure, moisture, and certification needs before final model selection.