Industrial Series: GS6110-IR

GS6110-IR Portable CO/CO₂ Analyzer

Handheld NDIR analyzer for on-site CO and CO₂ measurement

CO Range
0-2000 ppm
CO₂ Range
0-5 %vol
Weight
1.3 kg
Battery
10 hours
Product Overview

Overview

Compact portable analyzer with NDIR sensor for field measurement of CO and CO₂. Built-in pump, large display, and ruggedized housing for industrial environments.

Key Highlights
  • Built-in sample pump
  • Auto-zero and span check
  • Bluetooth data transfer
  • Ruggedized IP65 housing

Full Technical Specifications

Key Performance

Key Performance metrics for GS6110-IR
Metric Value Status
CO Range 0-2000ppm confirmed
CO₂ Range 0-5%vol confirmed
Accuracy ±2% of reading or ±5 ppm CO / ±0.01% CO₂ confirmed
Response <20 s T90 confirmed
Data Logging 5,000 readings confirmed

Measurement

Measurement specifications for GS6110-IR
SpecificationValue
Measuring PrincipleSingle-beam NDIR with auto-zero
CO Range0–2000 ppm
CO₂ Range0–5 %vol
Accuracy±2% of reading or ±5 ppm CO / ±0.01% CO₂
Response Time (T90)<20 s

Physical

Physical specifications for GS6110-IR
SpecificationValue
Dimensions (W×H×D)220 × 100 × 55 mm
Weight1.3 kg (with pump)
Housing MaterialRubberized ABS, IP65
Display3.5″ color LCD (sunlight-readable)

Electrical

Electrical specifications for GS6110-IR
SpecificationValue
BatteryLi-ion 7.4 V, 4400 mAh
Runtime10 hours
ChargingUSB-C, 2 hours
Data Logging5,000 readings

Environmental

Environmental specifications for GS6110-IR
SpecificationValue
Operating Temperature-10 °C to +50 °C
Storage Temperature-30 °C to +60 °C
Humidity0–95 % RH
AltitudeUp to 3,000 m

Certifications

Certifications specifications for GS6110-IR
SpecificationValue
IP RatingIP65
EMCEN 61326-1
Drop Test1.5 m
Bluetooth4.2 BLE

Where This Analyzer Fits

This model is mapped to the following industry applications and process duties.

HVAC & IAQ
Power Generation
Environmental

Deployment Environments

Common process environments where this model is evaluated.

Boiler tune-up
Indoor air quality
Vehicle emission testing
Stack spot checks

Certification Scope

Standards are listed with scope and status so engineering review can verify the applicable enclosure, area, and safety case.

Certification scope matrix for GS6110-IR
Standard Scope Variant Status Document
CE Portable CO/CO₂ analyzer Project variant approved On request
IP65 Ruggedized portable housing Project variant approved On request
UKCA / FCC Approvals listed in existing certification detail Project variant approved On request
CE IP65

Request Documentation

Request technical datasheets, user manuals, certificates, and application notes for this model.

Evidence Notes

case-study

Portable CO₂ survey records for building certification workflows

Application note based on the existing HVAC and building-management scenario: Bluetooth data transfer and zone tagging support CO₂ survey records for building-certification review. Survey duration depends on building layout, zone count, and reporting requirements.

Technical / Engineering Details

Technical & Engineering Details

Secondary engineering detail — expand each topic for the full measurement, envelope, sample-system, calibration, integration, maintenance and application evidence.

01 Measurement Principle and Limits

How the measurement is bounded

Single-beam NDIR with auto-zero for portable CO and CO₂ field measurement.

Requires

  • Pump-only sampling path stated in FAQ
  • Auto-zero using clean ambient air before measurement
  • Filter cartridge replacement in dusty environments

Interferents and Limits

  • H₂O vapor in unconditioned field samples
  • CO / CO₂ channel overlap must be handled by configured NDIR compensation
  • Diffusion-mode sampling is not supported by this pump-only SKU
  • Operation outside the stated ambient temperature and humidity ranges
02 Operating Envelope

Use these limits as selection inputs, then confirm sample condition, ambient exposure, and materials before quotation.

Ambient Temperature
-10-50 C
Humidity
0-95 %
relative humidity from Environmental specifications
Outside This Envelope
  • Diffusion-mode sampling
  • Field operation outside stated ambient and humidity ranges
03 Sample System Boundary

Sampling mode, conditioning components, and exclusions define where the analyzer responsibility ends and the sample system begins.

Sampling Mode
portable
Boundary Components
  • built-in sample pump
  • pump-only sampling path
  • Bluetooth data transfer
Boundary Exclusions
  • No external extractive conditioning system is declared for this portable SKU
  • Diffusion sampling is not supported
04 Calibration & Validation review

Calibration method, interval, traceability, and audit support are shown only when structured data is available.

Zero / Span Method

Auto-zero using clean ambient air; span check supported per feature list

Interval

Interval not stated in v1 source data

05 I/O & Integration

Signal outputs and communication interfaces shown from the published specification fields on this product page.

Data Logging

5,000 readings

DAHS Review Note

Confirm protocol map, channel naming, alarm states, and reporting format during project integration review.

06 Maintenance & Spares site-specific

Tasks, consumables, and access items are shown only when structured maintenance data is available.

Service Tasks
  • Filter cartridge replacement monthly in dusty environments
  • Pump service review against the stated operating-hour reference
  • Auto-zero and span-check review per site procedure
Consumables
  • Filter cartridge
  • Span gas when span check is performed
07 Application Evidence

Application context from complex industrial environments.

Case Study HVAC & Building Management

Application Context

Facilities teams auditing CO₂ levels in 50+ commercial buildings for WELL Building Standard certification face long survey timelines because manual zone notation and data transcription dominate the working day.

Architecture Response

GS6110-IR with Bluetooth data transfer and automatic zone-tagging compresses survey workflow into a single-day audit per building, supporting WELL evidence collection without manual transcription.

Survey Workflow Compression Bluetooth zone-tagged audit · single-day workflow
Selection Questions

Frequently Asked Questions

How often does the built-in pump need maintenance?

Diaphragm pump is rated for 5000+ hours between service checks. Filter cartridge should be replaced monthly in dusty environments.

Can I use it for vehicle emission testing?

Yes, the 0-2000 ppm CO range covers passenger vehicle exhaust. Use the optional exhaust probe accessory for safe insertion.

Is the Bluetooth connection secure?

Yes, Bluetooth 4.2 BLE with encrypted pairing. Data is transmitted to the GasLink mobile app (iOS/Android).

What is the warm-up time?

Under 60 seconds to measurement-ready. Auto-zero completes in 30 seconds using clean ambient air.

Can I switch between diffusion and pump mode?

The GS6110-IR uses pump-only sampling. For diffusion-mode applications, see the GS8110-O2 series.

Review GS6110-IR against site conditions

Send gas range, sample temperature, pressure, moisture, and certification needs before final model selection.