



ZS8100-C2H2 Process Acetylene Analyzer
TDLAS tunable diode laser acetylene analyzer for welding gas purity, chemical-synthesis feed (VAM / 1,4-BDO), and extractive transformer DGA workflows
- Range
- 0–100 / 0–1000 ppm / 0–5 %vol
- Accuracy
- ±2 % FS or ±1 ppm
- Response (T90)
- <5 s
- Detection Limit
- <0.5 ppm (DGA-useful)
Overview
The ZS8100-C2H2 is an in-line TDLAS acetylene analyzer built for industrial process duty — welding-gas header and blending-skid purity, semiconductor CVD precursor QA, and chemical-synthesis feed control on VAM and 1,4-BDO routes. Narrow-line diode-laser absorption supports selectivity across hydrocarbon, moisture, and pressure background drift that can constrain broadband sensors. For periodic DGA and laboratory confirmation, scope an unnumbered bench-top TDLAS workflow by project review; online transformer DGA is offered as a Conditional engineering-review path with oil-gas extraction module.
- TDLAS single-line laser absorption — reagent-free optical cell; filters and span gas remain service items
- Multi-range firmware covers DGA ppm to process %vol without optics change
- Engineered for extractive sample loops in hydrocarbon / synthesis gas matrices
- Bench-top TDLAS review path supports DGA and laboratory confirmation workflows
Full Technical Specifications
Key Performance
| Metric | Value | Status |
|---|---|---|
| Range | 0–100 / 0–1000 ppm / 0–5%vol (multi-range) | conditional* |
| Accuracy | ±2 % FS or ±1ppm (whichever greater) | conditional* |
| Response (T90) | <5 s | conditional* |
| Detection Limit | <0.5ppm (DGA-useful) | conditional* |
* Industry-typical TDLAS C₂H₂ values — shown as target scope; confirmed values are issued with the final datasheet at quotation.
Measurement
| Specification | Value |
|---|---|
| Measuring Principle | TDLAS (Tunable Diode Laser Absorption Spectroscopy) |
| Target Wavelength | Near-IR ≈ 1.5 μm (C2H2 absorption line) |
| Measurement Range | 0–100 ppm / 0–1000 ppm / 0–5 %vol (multi-range) |
| Lower Detection Limit | <0.5 ppm (DGA-useful) |
| Accuracy | ±2 % FS or ±1 ppm (whichever greater) |
| Repeatability | ≤1 % FS |
| Response Time (T90) | <5 s |
| Optical Path | Multi-pass absorption cell (Herriott / White-type, 1–10 m effective) |
Sample System
| Specification | Value |
|---|---|
| Sampling Mode | Extractive (heated probe + conditioning system) |
| Sample Temperature | Up to 180 °C (with heated line, application-dependent) |
| Sample Pressure | -30 to +500 mbar g |
| Recommended Conditioning | ZS-SCS-600 cool-dry / ZS-SCS-800 heated (project-dependent) |
| Online DGA | Conditional — requires oil-gas extraction module + hardware confirmation |
Environmental
| Specification | Value |
|---|---|
| Operating Temperature | -20 °C to +50 °C |
| Storage Temperature | -40 °C to +70 °C |
| Humidity | 0–95 % RH (non-condensing) |
| Ingress Protection | IP65 (standard) / IP66 (field enclosure) |
Electrical
| Specification | Value |
|---|---|
| Power Supply | 100–240 VAC, 50/60 Hz, 80 W max |
| Analog Output | 2 × 4–20 mA (isolated, configurable) |
| Digital Output | RS-485 Modbus RTU / HART 7 (optional) |
| Relay Outputs | 4 × SPDT (alarm, fault, maintenance, range) |
| Display | 5″ color TFT with local touchscreen HMI |
Physical
| Specification | Value |
|---|---|
| Dimensions (W×H×D) | 483 × 177 × 420 mm (19″ rack) / field enclosure optional |
| Weight | ≈15 kg (rack) / ≈32 kg (field enclosure) |
| Housing Material | Powder-coated aluminum enclosure; SS316L wetted parts on sample path |
| Mounting | 19″ rack (4U) / wall-mount / field enclosure |
Certifications
| Specification | Value |
|---|---|
| CE Marking | EU equipment directive compliance (target scope) |
| Hazardous Area | ATEX / IECEx — Conditional scope (confirmed per project) |
| EMC | EN 61326-1 |
| Quality System | ISO 9001:2015 manufactured |
| Application Standards | IEC 60599 / IEC 60567 / ASTM D3612 / IEEE C57.104 (DGA); CGA G-1.1 (welding) |
Where This Analyzer Fits
This model is mapped to the following industry applications and process duties.
Deployment Environments
Common process environments where this model is evaluated.
Certification Scope
Standards are listed with scope and status so engineering review can verify the applicable DGA reference method, welding-gas purity context, and hazardous-area case. Performance approvals are shown as target scope — current certification status for your configuration is confirmed at quotation; hazardous-area and DGA-standard scope is tracked as a Conditional engineering-review path, not a default catalogue claim.
| Standard | Scope | Variant | Status | Document |
|---|---|---|---|---|
| CE (EU declaration of conformity) | CE marking is a target scope; the EU Declaration of Conformity for your configuration is confirmed per project and supplied on request once issued | Project variant | target | On request |
| ATEX hazardous area | Optional Ex d enclosure listed as application-dependent | Project variant | conditional | On request |
| IEC 60599 / IEC 60567 / ASTM D3612 | DGA context only; oil-gas extraction and lab workflow confirmed per project | Project variant | conditional | On request |
| CGA G-1.1 | Welding-gas purity context; project sample handling confirmed per application | Project variant | conditional | On request |
| ISO 9001:2015 | Quality management system — manufactured under ISO 9001:2015 | Project variant | approved | On request |
Request Documentation
Request technical datasheets, user manuals, certificates, and application notes for this model.
Evidence Notes
Extracted C₂H₂ gas-phase DGA architecture
For transformer DGA and acetylene process work, the architecture places the TDLAS measurement on the extracted gas phase, then treats oil-gas extraction, hydrocarbon background, and sample conditioning as project-scoped boundaries rather than claiming direct oil measurement.
Technical & Engineering Details
Secondary engineering detail — expand each topic for the full measurement, envelope, sample-system, calibration, integration, maintenance and application evidence.
01 Measurement Principle and Limits
How the measurement is bounded
TDLAS targets a C₂H₂ absorption line in an extractive gas-phase cell for process acetylene, welding-gas QA, and extracted transformer DGA workflows.
Rejects
- Direct laser interrogation of transformer oil as a catalogue claim
- Online DGA without oil-gas extraction module
- Bench-top laboratory confirmation as the default continuous process path
Requires
- Extractive gas-phase sample
- Hydrocarbon matrix review
- Oil-gas extraction module for online transformer DGA
- ZS-SCS-600 or ZS-SCS-800 conditioning selected by moisture and oil-mist risk
Interferents and Limits
- C₂H₄ / C₂H₆ / CH₄ hydrocarbon background
- Moisture and pressure background drift
- Oil mist from welding-gas manifolds or extraction modules
- Rich CH₄ backgrounds require application calibration
02 Operating Envelope
Use these limits as selection inputs, then confirm sample condition, ambient exposure, and materials before quotation.
- Oil-phase measurement without extraction
- Unconditioned oil mist entering the optical cell
- Unreviewed hazardous-area enclosure scope
03 Sample System Boundary
Sampling mode, conditioning components, and exclusions define where the analyzer responsibility ends and the sample system begins.
- Heated probe or cool-dry conditioning
- Multi-pass optical cell
- ZS-SCS-600 cool-dry option
- ZS-SCS-800 heated option
- Oil-gas extraction module for online DGA when scoped
- Direct oil measurement
- Unfiltered oil-mist sample
- Online transformer DGA without extraction module
04 Calibration & Validation
Calibration method, interval, traceability, and audit support for this analyzer.
Zero / Span Method
Automatic zero-check plus manual span verification with certified C₂H₂ mixture
Interval
Site-specific
Reference Methods
IEC 60599 / IEC 60567 / ASTM D3612 DGA context; CGA G-1.1 welding-gas QA context
Span Gas Traceability
Certified C₂H₂ mixture selected for the project range
Audit Support
- IEC 60599 / IEC 60567 / ASTM D3612 DGA context
- CGA G-1.1 welding-gas QA context
05 I/O & Integration
Signal outputs and communication interfaces for control-system integration.
Output
4–20 mA / RS-485 Modbus / HART
Analog Output
2 × 4–20 mA (isolated, configurable)
Digital Output
RS-485 Modbus RTU / HART 7 (optional)
Relay Outputs
4 × SPDT (alarm, fault, maintenance, range)
DAHS Review Note
Confirm protocol map, channel naming, alarm states, and reporting format during project integration review.
06 Maintenance & Spares site-specific
Routine service tasks, consumables, and access requirements for this analyzer; exact intervals are site-specific.
- Check optical cell windows
- Service coalescing and particulate filters
- Verify zero-check function
- Run C₂H₂ span verification
- Certified C₂H₂ span gas
- Coalescing filter elements
- Window purge consumables where fitted
07 Application Evidence
Application context from complex industrial environments.
Application Context
Provincial grid operators running high-voltage substations need earlier-warning dissolved-gas analysis (DGA) on aging main transformers, where lab-return DGA cycles can miss the early C₂H₂ signature window that precedes a thermal-fault escalation.
Architecture Response
A ZS8100-C2H2 TDLAS analyzer network on the gas-phase side of vendor oil-gas extraction modules — across main-transformer banks — delivers continuous live C₂H₂ readings, so the early-warning C₂H₂ signature window becomes visible to the grid control center in minutes rather than days.
Frequently Asked Questions
Can the ZS8100-C2H2 perform online transformer DGA without an oil-gas extraction module?
IEC 60599 defines DGA against gases dissolved in transformer oil, not free head-space, so online DGA always needs an oil-to-gas extraction stage — head-space equilibrium or polymer membrane — to strip dissolved C2H2 into a carrier stream that TDLAS can read. Direct laser interrogation of the oil matrix remains a research-grade concept and has not displaced extraction modules in field service. The ZS8100-C2H2 ships tuned for the gas-phase side of the loop; pairing with a validated oil-gas extraction skid is therefore a Conditional engineering-review path rather than a drop-in capability, and extracted-sample DGA per IEC 60567 / ASTM D3612 remains the principal workflow.
How does the ZS8100-C2H2 separate C2H4 / C2H6 / CH4 overlap in DGA head-space?
The near-IR C2H2 overtone feature at ~1.5 μm is narrower than anything a broadband filter-photometer sees. The instrument tunes across the selected line centre, fits a Voigt profile, and subtracts adjacent hydrocarbon wings so C2H4, C2H6 and CH4 are handled as part of the declared DGA background instead of being treated as arbitrary mixtures. Accuracy is specified with a representative hydrocarbon background per IEC 60567 sample preparation; unusually rich backgrounds (for example >5 %vol CH4) are handled by a dedicated application calibration rather than the default factory cal.
What sample conditioning does the welding-gas manifold application need?
Metallurgical acetylene feed arrives dry but is typically entrained with oil mist from cylinder manifolds and blending skids. For header / blending-skid QA, the ZS-SCS-600 cool-dry chain is typically specified — coalescing filter, chiller to a stable 5 °C dew point, and 2 μm particulate catch — ahead of the analyzer cell. Heated sampling (ZS-SCS-800) is specified only when an upstream scrubber or wet-trap could condense on the cell window. CGA G-1.1 commodity-acetylene purity governs the spec envelope; the analyzer reports C2H2 %vol plus impurity ppm excursions against that spec.
What calibration cadence should I plan for routine process duty?
Under the GESHINE maintenance plan the TDLAS signal chain runs an automatic zero-check against a sealed reference cell at user-settable intervals (typical daily) and a manual span verification with a certified C2H2 mixture every 6 months for process duty, quarterly for DGA-rated service. Because the principle is optical-only (no chemistry consumable) there is no electrochemical cell or reagent to swap; the dominant service items are the laser module and the window purge, both field-replaceable without cell re-alignment.
When should I use a bench-top TDLAS workflow instead of the in-line ZS8100-C2H2?
The ZS8100-C2H2 is intended for continuous in-line / on-skid duty with optional ATEX Ex d enclosure, 24/7 operation, and 4–20 mA / Modbus hand-off to SCADA. The bench-top TDLAS review path serves DGA laboratory confirmation, inter-comparison, and periodic audit of portable cylinder mixtures — it trades continuous-duty packaging for a tighter multi-pass cell and metrology-grade calibration reports. Operations logging transformer DGA trend data online run the ZS8100; reference-sample sign-off belongs to the bench-top TDLAS review path, giving an online monitoring plus lab confirmation workflow.
Review ZS8100-C2H2 against site conditions
Send gas range, sample temperature, pressure, moisture, and certification needs before final model selection — we confirm specifications and return a quotation within 24 hours.

