Industrial Series: ZS-SCS-800

ZS-SCS-800 High-Temperature Heated Sampling System

Complete heated extractive system for corrosive and wet gas streams

Temperature
180°C continuous
Materials
SS316L / PTFE / Hastelloy
Flow Rate
1-5 L/min
Filtration
2 µm sintered
Product Overview

Overview

Fully heated sampling system maintaining 180°C from probe tip to analyzer inlet. Prevents condensation and sample loss in wet, corrosive flue gas applications.

Key Highlights
  • 180°C fully heated from probe to analyzer
  • Corrosion-resistant wetted materials
  • Automatic blowback cleaning
  • Redundant temperature monitoring

Full Technical Specifications

Key Performance

Key Performance metrics for ZS-SCS-800
Metric Value Status
Heated sample path 180C continuous confirmed
Sample flow 1-5L/min confirmed
Primary filtration 2 µm sintered SS316L in-stack + 0.5 µm secondary confirmed
Heated line length 30 m standard; 50 m optional confirmed
Blowback Automatic timed or manual confirmed

Measurement

Measurement specifications for ZS-SCS-800
SpecificationValue
System TypeHeated extractive
Temperature180°C continuous (probe to analyzer)
Flow Rate1-5 L/min
Filtration2 µm sintered SS316L in-stack + 0.5 µm secondary
BlowbackAutomatic timed or manual

Physical

Physical specifications for ZS-SCS-800
SpecificationValue
Dimensions (cabinet)600×800×400mm wall-mount
Weight45kg (excl. probe)
MaterialsSS316L / PTFE / Hastelloy C-276 (wetted)
Heated LineUp to 30m standard (50m optional)

Electrical

Electrical specifications for ZS-SCS-800
SpecificationValue
Power230VAC 50/60Hz 1200W (heated line + cabinet)
ControllerPLC with 7″ HMI touchscreen
Temperature Zones3 independently controlled
Alarms4×relay (over-temp under-temp fault flow)

Environmental

Environmental specifications for ZS-SCS-800
SpecificationValue
Ambient-30°C to +50°C
Stack Gas TempUp to 400°C at probe tip
Stack Pressure-50 to +200 mbar
Corrosive GasHCl HF SO₃ compatible (Hastelloy option)

Certifications

Certifications specifications for ZS-SCS-800
SpecificationValue
CEMSEN 15267 sampling compliance
EMCEN 61326-1
SafetyEN 61010-1
MaterialsPED 2014/68/EU compliant

Where This Analyzer Fits

This model is mapped to the following industry applications and process duties.

Power Generation
Environmental Compliance
Petrochemical

Deployment Environments

Common process environments where this model is evaluated.

CEMS flue gas sampling
Incinerator emissions
Acid gas streams
High-moisture processes

Certification Scope

Standards are listed with scope and status so engineering review can verify the applicable enclosure, area, and safety case.

Certification scope matrix for ZS-SCS-800
Standard Scope Variant Status Document
EN 15267 sampling compliance as listed in the current published certification specification Project variant approved On request
EN 61010-1 electrical safety for the sampling-system cabinet Project variant approved On request
EN 61326-1 EMC for the sampling-system controller Project variant approved On request
PED 2014/68/EU pressure-equipment material compliance listed in the current published certification specification Project variant approved On request
CE

Request Documentation

Request technical datasheets, user manuals, certificates, and application notes for this model.

Evidence Notes

case-study

High-particulate acid-gas CEMS sampling architecture

Waste-to-energy flue-gas service combines particulates with HCl-bearing corrosion risk. The case-study architecture uses Hastelloy C-276 wetted parts, 180 C heat tracing, and automatic blowback to keep the sample path above dew point while managing filter loading.

application-note

Heated extractive path boundary

The system is positioned upstream of rack-mount analyzers that require a clean, heated sample at atmospheric pressure; material selection and heated-line length remain application-engineering checks.

Technical / Engineering Details

Technical & Engineering Details

Secondary engineering detail — expand each topic for the full operating envelope, maintenance and application evidence.

01 Operating Envelope

Use these limits as selection inputs, then confirm sample condition, ambient exposure, and materials before quotation.

Ambient Temperature
-30 to 50 C
Dew Point
160 C
typical acid dew-point reference from the FAQ; sample path is maintained at 180 C
Dust
High-particulate flue-gas duty with automatic blowback; numeric dust limit not stated for this system
cycle timing set by site dust loading and filter differential behavior

Corrosive Agents

  • HCl
  • HF
  • SO3 with Hastelloy option

Wetted Materials

  • SS316L
  • PTFE
  • Hastelloy C-276
Outside This Envelope
  • Probe-tip duty above 400 C without engineering review
  • HCl above 50 mg/m3, HF, or high SO3 without Hastelloy C-276 wetted parts
  • Heated-line runs above 50 m without added heating zones and temperature monitoring
02 Maintenance & Spares confirmed

Routine service tasks, consumables, and access requirements for this analyzer; exact intervals are site-specific.

Service Tasks
  • Inspect and replace in-stack and secondary filter elements according to particulate loading
  • Verify automatic blowback timing and instrument-air supply before high-dust campaigns
  • Check all three heated temperature zones and alarm relays during planned service
  • Review wetted-material selection when HCl, HF, or high SO3 conditions change
Consumables
  • Sintered in-stack filter element
  • Secondary filter element
  • Heated-line service parts
Service Access

Wall-mount cabinet with PLC/HMI status plus probe and heated-line service points

03 Application Evidence

Application context from complex industrial environments.

Case Study Waste-to-Energy

Application Context

Waste-incinerator CEMS installations face chronic downtime from sample-line blockage and HCl-driven probe corrosion in high-particulate flue gas, where each downtime event triggers a regulatory non-availability notification.

Architecture Response

ZS-SCS-800 with Hastelloy C-276 wetted parts and automatic blowback supports sustained CEMS availability through high-particulate, HCl-bearing flue-gas duty, so non-availability notifications do not dominate the operations log.

High-Particulate Architecture Hastelloy C-276 · automatic blowback
Selection Questions

Frequently Asked Questions

Why is 180°C heating important?

Maintaining sample temperature above the acid dew point (~160°C for typical flue gas) prevents condensation of water, SO₃, and HCl. Condensation causes sample loss, corrosion, and cross-contamination that invalidates measurements.

What is the maximum heated line length?

Standard: 30 meters. Extended: 50 meters with additional heating zones. Longer runs require increased power supply capacity and additional temperature monitoring points.

When should I choose Hastelloy over SS316L?

Hastelloy C-276 is required for flue gas containing HCl >50 mg/m³, HF, or high SO₃ concentrations — typically waste incinerators, chlor-alkali plants, and glass furnaces. SS316L is adequate for standard coal/gas combustion.

How does the automatic blowback work?

Compressed instrument air (6 bar) is periodically pulsed back through the in-stack filter to dislodge accumulated particulates. Cycle timing is configurable from 5 minutes to 24 hours depending on dust loading.

What analyzers is the ZS-SCS-800 compatible with?

Compatible with all GESHINE rack-mount analyzers (ZS8xxx series, ZS6xxx series). Also compatible with most third-party analyzers requiring clean, heated sample at atmospheric pressure.

Review ZS-SCS-800 against site conditions

Send gas range, sample temperature, pressure, moisture, and certification needs before final model selection.